Sevcon Gen4 Fault Codes and LED Flash Codes Explained

Sevcon Gen4 AC traction controller in electric forklifts. LED flash codes, fault table, reading faults via DVT and CANbus, contactor and fuse notes.

Updated November 6, 2026

The Sevcon Gen4 drives AC traction motors in electric forklifts. When a fault occurs, it first protects the operator and the truck, sends an EMCY message on the CANbus, flashes the green LED and logs the fault. This guide summarises the fault codes from the Applications Reference Manual 177/52701 (Rev. 3.3) and the size 8 and 10 manuals.

Work on the traction battery, line contactor and fuse only according to the truck manufacturer's and the controller manufacturer's instructions.

How to read a fault

LED. A green LED on the housing stays lit while there is no fault. With a fault it flashes a fixed number of times, pauses and repeats the pattern. In multi-node systems only the affected controller flashes. The size 8 and 10 manual describes the LED indication explicitly for size 8.

DVT. Sevcon's Windows tool DVT shows status and the fault list.

CANbus. With any configuration software you can listen to the EMCY message or query objects directly. Object 5300h returns the active faults. Sub-index 1 gives the count. Write a position into sub-index 2 (0 is the highest priority) and sub-index 3 returns the fault ID. Object 5610h gives a plain text description when you write the ID to sub-index 1 and read sub-index 2.

The bus needs a 120 Ω termination at both ends. If the Gen4 is an end node, link pins 2 and 24 on the customer connector.

Fault categories

The manual defines five levels. They decide who can clear the fault.

LevelConsequenceCleared by
RTB (Return to base)System shuts down immediatelySevcon personnel
VS (Very severe)System shuts down immediatelyauthorised service personnel
S (Severe)System shuts down immediatelykey switch off and on
DI (Drive inhibit)Driving is prevented, braking still worksdeselect all drive switches, then reselect
I (Information)no immediate action, possible power cutbacknot latched

Fault table by LED flashes

The manual itself notes that a complete fault table is still to come, so check your firmware against current manufacturer documentation.

LEDFaultLevelFirst check according to the manual
0 (off)Internal hardware not operatingRTBno user check given
1Configuration item out of range, corrupt configuration data, hardware and software mismatchVSbring the value into range, object 5621h names the affected object
2Direction selected with handbrake on, drive switch active at power up, seat fault, both directions for more than 200 ms, inch faultsDIrelease handbrake, reset switches, check seat switch
2Invalid steer switch statesVScheck steer switches
3Fault in power stage (e.g. MOSFET short circuit)VSno user check given
3Hardware over voltageVSreduce battery voltage below the maximum, check objects 2C01h and 4612h
3Hardware over currentVScheck motor load, wiring and motor parameters
4Line contactor welded or did not closeScheck contactor and wiring
5Motor open circuitScheck motor and wiring
5Power steer module (PST) faultDIcheck the PST
6Throttle above 20 percent at power upDIrelease the demand
6Analogue input or output faultVScheck input or output wiring
7Battery empty, voltage too lowIcharge the battery, raise voltage
7Voltage too high with contactor closedIreduce battery voltage
7Voltage too high with contactor openSisolate the controller, investigate the high voltage
7Precharge failure (capacitor below 5 V after precharge)VScheck wiring for a short between positive and negative
8Controller or motor too hot, controller or motor too coldIreduce load, let it cool or warm up, check motor thermistor
8Heatsink over temperatureVSremove load, let it cool down
10Pre-operational, I/O initialising, RPDO timeoutI to SDVT sets operational, check CANbus wiring and PDO configuration
11Encoder fault (wire off, signals out of range)VScheck encoder wiring, calibrate sin/cos signals
11Over current or current control (PMAC motor)VScheck motor load, wiring, motor parameters
12Communication errorScheck CANbus wiring and CANopen configuration
13Internal software or hardware, current sensor auto zeroRTBno user check given
13DSP parameter errorRTBcycle the key switch
14EMCY from a third party nodeI to RTBcheck CANbus wiring and the third party node
15Service requiredIservice the truck, reset service hours

The size 8 and 10 manual also lists group 9 for a contactor coil short circuit, without set conditions.

Object 5100h sub-index 1 shows battery voltage at the key switch input, sub-index 2 shows capacitor voltage at the controller's positive terminal.

Line contactor, precharge and fuses

After power up the Gen4 first charges its input capacitors through the key switch line to an adjustable share of battery voltage (object 5820h, 50 to 90 percent). Only then does it close the line contactor. With several controllers, the master handles precharge for the slaves.

The manual assigns these Albright line contactors to the Gen4 peak output current. Never wire the coil to the supply side of the key switch. Use the output supply pins instead.

Peak currentCoilCatalogue numberType per manual
up to 450 A24 V828/37024SW200-29
up to 450 A48 V828/57026SW200-20
up to 450 A80 V828/67010SW200-460
up to 650 A24 V828/39001SW200

The main fuse can be mounted directly on the controller body. The B+ terminal is only a connection point for the fuse. If you connect the battery cable to the other end, the installation runs without a fuse.

Input voltagePeak currentFuseCatalogue number
72 V and 80 V180 A200 A858/83339
36 V and 48 V275 A250 A858/29043
24 V and 36 V300 A325 A858/32044
72 V and 80 V350 A355 A858/32045
24 V to 48 V450 A425 A858/81990
72 V and 80 V550 A500 A858/32043
24 V to 48 V650 A750 A858/33021

Size the key switch fuse F2 for the larger of two values. The first is the sum of the drive currents plus 1 A for internal circuits. The second is the precharge demand. In the manual's example with two contactors at 2 A each, the result is 7 A.

Signal wiring

The manual specifies 0.5 to 1.5 mm² for signal wires. For CANbus and speed sensors it recommends twisted, shielded cable. The screen goes to the Gen4's negative terminal. The mating connector kit with 35 ways for signal wiring is 661/27091.

Matching parts from the catalogue

The linked parts come from our Sevcon catalogue. Check fitment before ordering against the type plate and the part number.

FAQ

What does it mean when the LED is steady or off?

A steady light means no fault according to the manual. No light is listed in the table as an internal hardware fault.

How do I clear a fault?

For S faults, switch the key switch off and on. For DI faults, deselect all drive switches and reselect. Authorised service personnel clear VS faults and Sevcon clears RTB faults.

What do I check at four flashes?

Four flashes point to a line contactor fault. Either the contactor was closed at power up or after the coil dropped out, or it did not close although the coil was energised. Check the contactor and its wiring.

Do you need one of the parts mentioned? We deliver the matching part with a quote the same day, and express shipping is possible.

Matching parts and pages

Need one of these parts?

Send us the part number or the fault code. You get your quote the same day, express shipping possible.

Request a quote